Summary
Micro load cell designed for limited room force measure
Application
limited room force measure
Detail information
1.load cell capacity
Capacity (kg) | 10,20,50,100,200,500
|
2. load cell size and force direction


3. load cell parameter
technical parameters |
Specifications | Technique |
Capacity | 10,20,50,100,200,500kg |
Rated output | 1.0±10%mV/V |
Zero balance | ± 0.03mV/V |
Non-linearity | ≤0.5%F.S. |
Hysteresis | ≤0.3%F.S. |
Repeatability | ≤0.2%F.S. |
Temp.effect on output | 0.1%F.S./10℃ |
Temp.effect on zero | 0.1%F.S./10℃ |
Input impedance | 700±20Ω |
Output impedance | 700±10Ω |
Insulation | ≥5000MΩ/100VDC |
Recommended excitation | 5~15V |
Maximum excitation | 20V |
Compensated temp range | -10~60℃ |
Operation temp range | -20~80℃ |
Safe overload | 150%F.S. |
Ultimate overload | 200%F.S. |
Cable size | φ3×3000mm |
Material | stainless steel |
load cell weight | 0.2kg |
4.load cell wiring code