Summary
anchor load cell is designed to used in Port Crane
Application
Port Crane
Detail information
1.load cell 3D picture and capacity

2. load cell size and force direction



3. load cell parameter
Specifications
| Technique
|
Capacity
| 20t
|
Reted output
| 1.0~1.5mV/V
|
Zero Balance
| ±0.06mV/V
|
Non-linearity
| ≤0.1%F.S.
|
Hysteresis
| ≤0.1%F.S
|
Repeatability
| ≤0.1%F.S
|
Input impedance
| 350±20Ω
|
Output impedance
| 300±10Ω
|
Temp.effect on output
| 0.05%F.S./10 ℃
|
Temp.effect on zero
| 0.05%F.S./10 ℃
|
Insulation resistance
| ≥5000MΩ/100V(DC)
|
Recommended excitation
| 5~15V
|
Maximum excitation
| 20V
|
Compensated Temp Range
| -10~40 ℃
|
Operating Temp Range
| -20~60 ℃ |
Safe overload | 150%F.S.
|
Ultimate overload
| 200%F.S
|
Cable size
| φ5/6x1m
|
4.load cell wiring code