Summary
weigh module designed for Process weighing control
Application
Process weighing control
Detail information
1.weigh module capacity
Capacity | 0.25,2,5,10,15,20t |
2. weigh module size and installation


3. weigh module parameter
technical parameters |
Specifications | Technique |
Capacity | 0.25,2,5,10,15,20t |
Rated output | 2.0/3.0±10%mv/v |
Zero balance | ±2%F.S. |
Non-linearity | ≤0.03%F.S. |
Hysteresis | ≤0.03%F.S. |
Repeatability | ≤0.03%F.S. |
Creep (30 Min) | ≤0.03%F.S. |
Temp.effect on output | 0.025%F.S./10℃ |
Temp.effect on zero | 0.025%F.S./10℃ |
Input impedance | 385±5Ω |
Output impedance | 350±5Ω |
Insulation | ≥5000MΩ/100VDC |
Recommended excitation | 10V |
Maximum excitation | 15V |
Compensated temp range | -10~60℃ |
Operation temp range | -20~80℃ |
Safe overload | 150%F.S. |
Ultimate overload | 200%F.S. |
Cable size | φ5*6000mm |
IP Class | P65 (<500kg) IP68 (≥500kg) |
material | stainless steel/alloy steel |
4.load cell wiring code