1.load cell  capacity

 

Capacity300g,500g,1,1.5,2,3,4,5  kg


 

2. load cell size and force direction

 

 

501 S.png


501 F.png


 

3. load cell parameter

 

technical parameters
SpecificationsTechnique
Capacity300g,500g,1,1.5,2,3,4,5   kg
Accuracy   classC3
Rated output1.0±10%mV/V(300g,500g)2.0±10%mV/V(1~5kg)
Zero balance±2%F.S.
Non-linearity≤0.015%F.S.
Hysteresis≤0.015%F.S.
Repeatability≤0.015%F.S.
Creep(30min)≤0.0166%F.S.
Temp.effect   on output0.017%F.S./10℃
Temp.effect   on zero0.02%F.S./10℃
Input   impedance380±40Ω
Output   impedance380±40Ω
Insulation≥5000MΩ/100VDC
Recommended   excitation5~15V
Maximum   excitation20V
Compensated   temp range-10~40℃
Operation   temp range-25~70℃
Safe overload150%F.S.
Ultimate   overload200%F.S.
Cable sizeΦ3000mm
Weight   approx.0.1kg
Materialaluminum alloy


 

4.load cell wiring code


f1ce51311c6b50c3a3b88747e771684.png