load cell designed for industrial weighing system

Summary

 

industrial weighing system load cell FA504


Application 


industrial weighing system

 

Detail information

 

1.load cell  capacity

 

 

Capacity3,6,10,20 ,30kg


 

2. load cell size and force direction

 

 

504 s.png


504 f.png



 

3. load cell parameter

 

technical parameters
SpecificationsTechnique
Capacity3,6,10,20 ,30kg
Accuracy   classC3
Rated output2.0±10%mV/V
Zero balance±2%F.S.
Non-linearity≤0.015%F.S.
Hysteresis≤0.015%F.S.
Repeatability≤0.015%F.S.
Creep(30min)≤0.017%F.S.
Temp.effect   on output0.02%F.S./10℃
Temp.effect   on zero0.02%F.S./10℃
Input   impedance405±10Ω
Output   impedance350±5Ω
Insulation≥5000MΩ/100VDC
Recommended   excitation5~15V
Maximum   excitation20V
Compensated   temp range-10~40℃
Operation   temp range-20~60℃
Safe overload150%F.S.
Ultimate   overload200%F.S.
Cable sizeΦ4×400mm
Weight   approx.0.25kg
Materialaluminum alloy
Max.platform   size300mm×300mm


 

4.load cell wiring code


f1ce51311c6b50c3a3b88747e771684.png

DESCRIPTION

industrial weighing system load cell FA504